The email usually arrives on a Monday. A buyer in Europe likes your quotation and your lead time, and then adds one line at the bottom: “Please send the CE certificate, the PED declaration and the technical file.”
If you have never exported to the EU, that line can stall a deal for weeks. It stalls just as often on the buyer’s side, when a purchaser in a plant or a trading company gets a “CE certificate” from a supplier and is not sure what it is worth.
This guide is for both people. Whether you are the manufacturer getting ready to export or the buyer checking a supplier, you will find out what CE marking is, which EU rules touch valves and electric actuators, what a notified body does, and which documents are worth asking for. Facts from official sources carry numbers like [1] and are listed under Sources at the end. Facts about Cair come from Cair’s own web pages, which are linked where they appear.
One caution before we begin. This is a general explainer, not legal advice. The rules depend on your exact product, so confirm the details with a notified body or a compliance consultant before you ship.
What CE marking actually is
CE marking is not a quality badge, and in most cases it is not a certificate handed over by a lab. The European Commission describes it as the end of a process the manufacturer runs: work out which legislation applies, check the product against it, prepare technical documentation, issue a declaration of conformity and then put the mark on the product [1].
The only time an outside body must check the product is for higher-risk products. Then an independent notified body, appointed by national authorities, has to assess it and, after a successful assessment, issues certificates [1]. For many products the manufacturer does the checking and takes responsibility for the result.
That is why a PDF called “CE certificate” can mean very different things. It might be a notified body’s certificate. It might be a manufacturer’s own declaration. Ask which one you are looking at.
The seven steps, in plain language
The Commission lists these steps for manufacturers [1]:
- Find the legislation that applies. More than one directive or regulation can apply to the same product, and the page says other EU rules, on chemicals or the environment for example, may apply as well.
- Check the product-specific requirements in each of them, including the harmonised standards.
- Decide whether a notified body is needed. Notified bodies can be found in the NANDO database.
- Test the product and check conformity. When a notified body is involved, it usually verifies the quality management system, the product design and compliance with the essential requirements.
- Prepare the technical documentation. It must exist before you apply to a notified body or, at the latest, when you place the first product of that type on the market.
- Issue the EU declaration of conformity. It must carry the manufacturer’s name and address, the essential characteristics of the product, the notified body’s number where one was involved, and a legally binding signature.
- Affix the CE marking. It goes on the product, visibly and legibly, or on the packaging and documents if that is not possible. Its parts have the same vertical height, no smaller than 5 mm, and the notified body’s number sits next to it where one was involved.
For manufacturers based outside the EU, the Commission page says copies of the technical documentation must be kept by the manufacturer or by an authorised representative established in the EU [1]. If you are an Indian exporter, sort out who that representative is early.
Which EU rules apply to valves and electric actuators
There is no single “valve directive.” Several apply, depending on what you make. The table shows the ones that come up most often for valves and electric actuators. Which of them applies to a given model is for you and your notified body to confirm.
| Rule | What it covers | Main point from the source |
| Pressure Equipment Directive 2014/68/EU (PED) | Pressure equipment and assemblies above 0.5 bar | Manufacturers complete the conformity procedure that matches the equipment’s category [2] |
| ATEX Directive 2014/34/EU | Equipment for potentially explosive atmospheres | Rules depend on equipment category and on whether it is electrical [3] |
| Low Voltage Directive 2014/35/EU | Electrical equipment in set voltage ranges | 50 to 1000 V AC and 75 to 1500 V DC [4] |
| EMC Directive 2014/30/EU | Electromagnetic emissions and immunity | Equipment must comply when placed on the market [5] |
| Machinery Regulation (EU) 2023/1230 | Machinery, including partly completed machinery | Applies from 20 January 2027 and replaces Directive 2006/42/EC [6] |
The PED and valves
The PED applies to pressure equipment with a maximum allowable pressure above 0.5 bar [2]. The Directive defines pressure accessories as “devices with an operational function and having pressure-bearing housings” [7]. A valve fits that wording on its face, so the PED is the first place to look. Whether your valve is actually in scope depends on its size, its pressure and the fluid it handles.
Article 4 sets limits. For example, piping for fluids in Group 1 is covered when the DN is greater than 25, and piping for Group 2 liquids is covered when the PS is greater than 10 bar and the DN is greater than 200 [7]. Safety and pressure accessories are covered when they are intended for equipment above those limits [7]. Check the fluid group of your medium in the Directive itself before drawing any conclusion.
What if you are below the limits? Article 4(3) says such equipment must follow the sound engineering practice of a Member State and “shall not bear the CE marking” under the PED [7]. So a small valve without a PED mark is not necessarily a red flag. It is still fair for a buyer to ask what standard it was built to.
Above the limits, the route depends on the equipment’s category. The modules include internal production control (A and A2), design or type examination by a notified body (B), final assessment by a notified body with a Certificate of Conformity (F and G), and quality assurance systems audited by a notified body (D, E and H) [2]. The CE marking must be followed by the notified body’s identification number where that body is involved in the production control phase [8].
Two details from the Directive’s text are worth knowing before you draft your declaration. The EU declaration of conformity has to be kept up to date and translated into the language or languages required by the Member State where the equipment is placed on the market. And where several Union acts apply, a single declaration can cover them [8].
ATEX for explosion proof actuators
If an actuator will sit in a potentially explosive atmosphere, ATEX comes in. The Directive splits equipment into three categories: 1 and 2 for higher-risk areas, 3 for low-risk areas [3]. Electrical equipment in Categories 1 and 2 must be tested and certified by an EU notified body, and the manufacturer must hold a quality system certified by one. Non-electrical Category 2 equipment needs no notified body product assessment, but its technical documentation must be stored with an ATEX notified body. Category 3 equipment is the manufacturer’s own responsibility [3].
Electrical and EMC rules
An electric actuator is electrical equipment, so the Low Voltage Directive and the EMC Directive enter the picture. The Low Voltage Directive covers equipment with an input or output voltage of 50 to 1000 V AC or 75 to 1500 V DC [4]. A 220 V or 415 V AC actuator sits inside that range. A 24 V or 12 V DC version sits below it. That does not mean a low-voltage actuator is free of obligations. Ask the manufacturer which directives it applied and why.
On EMC, the Commission page says harmonised standards give a presumption of conformity once they are listed in the Official Journal, and that voluntary or additional certificates are not a recognised means of proving compliance [5]. In practice, a test report on its own is not the same as a declaration of conformity.
The Machinery Regulation
Machinery rules are changing. Regulation (EU) 2023/1230 applies from 20 January 2027 and replaces Directive 2006/42/EC. It also covers partly completed machinery, which may be made available only if it meets the relevant essential health and safety requirements in Annex III [6]. Whether a particular actuator counts as machinery, partly completed machinery or neither depends on the product, so ask your supplier or notified body which regime applies and which date matters for your shipments.
Manufacturer, notified body, authorised representative: who does what
- The manufacturer prepares the technical documentation, runs or arranges the conformity assessment, signs the declaration and affixes the mark [1].
- The notified body steps in for higher-risk products and issues certificates after a successful assessment [1].
- The authorised representative in the EU keeps copies of the technical documentation when the manufacturer is outside the EU [1].
Under the PED, the manufacturer takes responsibility for compliance by drawing up the declaration [8].
Documents an EU buyer will ask for
Whether you are the seller or the buyer, this is a sensible checklist:
- EU declaration of conformity for the exact model, listing every directive applied
- Notified body certificate and its identification number, where one was involved
- The harmonised standards or other standards the product was built to
- Material certificates and test reports for the order
- Technical documentation access through the manufacturer or the EU authorised representative
- For explosion proof actuators, the ATEX certificate for that exact model and category
- Installation and operating instructions in the language the destination country requires
Some of these are not in the sources above, so treat the list as a practical suggestion rather than a legal requirement.
What Cair says about its certifications
Cair’s who we are page says the company has been designing, manufacturing and supplying manual and electrically actuated valves since 2002, describes itself as ISO certified (9001:2015), and says it has an actuation test lab that checks products before delivery using bench testing and stress tests that simulate working conditions. The FAQ cites ISO 9001:2015, plus CE and ATEX for its explosion proof actuators.
On the explosion proof electric actuators page, Cair states that it is certified by CCOE and PESO, and that its designs are approved by ATEX, CE, IEC and ISI. The page lists a three phase explosion proof quarter turn actuator at 415 V AC with torque up to 2500 Nm, and all three models listed there are stated to include manual override. Cair’s single phase quarter turn actuator page lists IEC/EN 15714-2 among its standards, along with IEC-60034-1 and IS-996.
Those are Cair’s own statements at the company or category level. For a purchase order, ask for the declaration of conformity and any notified body certificate for the exact model you are buying. The certificates page shows the approvals and registrations Cair has published, and you can request anything model-specific through the inquiry form or the contact page. The service page also lists pre-order services for technical and formal details, which is where export paperwork questions belong.
Common mistakes
Treating CE as one certificate. It is a mark backed by a declaration, and sometimes by a notified body certificate. The declaration should name every directive applied [8].
Forgetting the number. If a notified body was involved, its identification number should appear next to the mark [1].
Marking what should not be marked. Equipment below the PED limits must not carry the CE marking under that Directive [7].
Ignoring the date. The Machinery Regulation applies from 20 January 2027 [6]. Plan for it if your products or shipments run past that date.
Leaving the EU side until last. The technical documentation has to be kept by the manufacturer or an EU authorised representative [1].
Quick questions
Is CE marking mandatory for every valve sold in Europe? Not under every directive. For PED equipment below the limits, the Directive says it must not carry the CE marking [7]. Other directives may still apply to the same product, such as ATEX or the electrical ones for an actuator.
Do I always need a notified body? No. The Commission page says an independent notified body is needed for higher-risk products [1]. Under ATEX, for instance, Category 3 equipment is the manufacturer’s own responsibility [3].
Where do I find a notified body? In the NANDO database, which the Commission page points to [1].
Can one declaration cover several directives? Under the PED, where several Union acts apply, a single declaration can be drawn up [8].
Next step
If you are weighing a supplier or planning an export order, send the model, quantity, destination country and the directives your buyer has named through Cair’s inquiry form. You can also browse the electric actuators, motorized valves and the catalogue first, or read more on the blog.
Sources
- [1] Manufacturers, CE marking, European Commission. https://single-market-economy.ec.europa.eu/single-market/goods/ce-marking/manufacturers_en
- [2] Pressure Equipment Directive, tuv.com. https://www.tuv.com/world/en/pressure-equipment-directive.html
- [3] ATEX Directive 2014/34/EU, TUV SUD. https://www.tuvsud.com/en-us/services/product-certification/atex-directive-2014-34-eu
- [4] Low Voltage Directive (LVD), European Commission. https://single-market-economy.ec.europa.eu/sectors/electrical-and-electronic-engineering-industries-eei/low-voltage-directive-lvd_en
- [5] Electromagnetic Compatibility (EMC) Directive, European Commission. https://single-market-economy.ec.europa.eu/sectors/electrical-and-electronic-engineering-industries-eei/electromagnetic-compatibility-emc-directive_en
- [6] Regulation (EU) 2023/1230 on machinery, EU-OSHA. https://osha.europa.eu/en/legislation/directive/regulation-20231230eu-machinery
- [7] Directive 2014/68/EU (PED), Chapter 1 (Articles 2 and 4), legislation.gov.uk. https://www.legislation.gov.uk/eudr/2014/68/chapter/1/data.htm?view=plain
- [8] Directive 2014/68/EU (PED), Chapter 3 (Articles 14 to 19), legislation.gov.uk. https://www.legislation.gov.uk/eudr/2014/68/chapter/3/data.htm?view=plain